Match the hotend thermistor’s exact model to sensor_type in Klipper’s printer.cfg. Restart Klipper and verify the cold temperature reading and heater response. Once both checks pass, run PID_CALIBRATE for extruder, then run SAVE_CONFIG. Klipper Configuration Reference · Klipper Configuration Checks
Match the thermistor to a Klipper profile
A negative temperature coefficient (NTC) thermistor’s resistance falls as it heats up. A 100K label alone can’t identify the profile. For example, SEMITEC specifies a rated zero-power resistance of 100 kΩ at 25°C for both its 104NT-4-R025H42G and 104NT-4-R025H43G parts, with different beta values over the same temperature interval. SEMITEC NT Thermistor specifications
Look for the exact part number or named Klipper profile in the documentation for your hotend or replacement sensor. Klipper Configuration Changes
| Documented sensor or profile | Klipper sensor_type |
|---|---|
| Generic 3950 profile | Generic 3950 |
Edit the sensor settings in printer.cfg
E3D lists the Semitec 104NT-4-R025H42G as the sensing element in its Classics 104NT cartridge. E3D 104NT specifications
Check the settings against your hardware. Klipper Configuration Checks
| Setting | When to check |
|---|---|
sensor_pin | Check this setting if the temperature reading looks wrong. |
heater_pin | Check this setting if the temperature does not rise during the heater check. |
Define a custom thermistor
These values recreate Klipper’s deprecated NTC 100K beta 3950 definition for a setup that specifically needs that older model. Use the values for your own part when defining a different sensor. Klipper Configuration Changes · Klipper Configuration Reference
temperature1: 25
resistance1: 100000
beta: 3950
Verify the reading before PID tuning
Follow these temperature and heater checks from Klipper’s configuration guide. Klipper Configuration Checks
- Save
printer.cfg. SendRESTART, thenSTATUSin the console to check that the configuration loaded. - With the heater off, check the temperature graph. The cold nozzle reading should be present and should not be increasing. If the reading looks wrong, check
sensor_typeandsensor_pinbefore heating. If the temperature rises with the heater off, cut power to the printer. - Once the cold reading looks right, enter 50°C in the extruder temperature box and press Enter. The nozzle reading should start rising within about 30 seconds. Select Off in the extruder temperature drop-down. If the temperature did not rise, check
heater_pin. If it rose, check after several minutes that the nozzle temperature has started returning toward its initial room temperature.
Run and save the hotend PID tune
Run the tune from the command console after the temperature and heater checks pass. This is Klipper’s 170°C example. The command heats the hotend to the target and then cycles the heater to calculate PID settings. Klipper Configuration Checks · Klipper G-Codes
PID_CALIBRATE HEATER=extruder TARGET=170
After calibration completes successfully, run the command below. It writes the settings to printer.cfg and restarts Klipper’s host software. The hotend’s saved settings include control: pid and the three coefficients pid_Kp, pid_Ki, and pid_Kd. Klipper G-Codes · Klipper PID calibration implementation
SAVE_CONFIG
Evidence and limits. On November 26, 2026, the settings and commands were checked against Klipper’s documentation, including the v0.14.0 configuration checks and command reference, and the published E3D and SEMITEC specifications. The procedure was not run on a printer for this guide.